Power factor correction and load profiling
If your TNB bill carries a low power factor penalty, or your factory runs motors, compressors and drives, we measure the real load first and then size the capacitor bank — so you pay for what is needed, not a guess.
Scope of work
Measure, design, install, verify
Load profiling
Profil beban
- A power analyser logs voltage, current, kW, kVA, kVAR, power factor and harmonics at your main incomer, typically over 7 to 14 days.
- Profile shows peaks, idle load, shift patterns and when the power factor drops below the 0.85 threshold used for TNB penalty billing on applicable tariffs.
- Harmonic distortion (THD) is recorded so we know whether a plain capacitor bank is safe or a detuned reactor is required.
- Findings summarised in a short report with the recommended kVAR rating and step configuration.
Correction equipment
Peralatan pembetulan
- Automatic power factor correction (APFC) panels with multi-step capacitor banks and a controller.
- Detuned reactors (typically 5.67% or 7%) where harmonics or resonance risk is present.
- Fixed capacitors at large motors, or centralised correction at the main switchboard.
- Existing capacitor banks inspected, tested and repaired or replaced when capacitors have aged or failed.
Verification and savings
Pengesahan
- Before and after readings so the power factor improvement is documented, not assumed.
- Reduced current and kVA demand, which frees capacity on transformers and cables.
- Support for your own energy reporting and, for large users, for EECA 2024 and energy audit work.
- Follow-up checks at 3 to 6 months to confirm steps are switching correctly.
Who it’s for
Where this work fits
Factories with motors and compressors
Inductive loads pull power factor down; correction removes penalties and releases transformer capacity.
Cold storage and F&B plants
Refrigeration compressors cycle constantly, making profiling essential before sizing a bank.
Commercial buildings
Chillers, lifts and large aircond plants on maximum-demand tariffs benefit from stable power factor.
Plants with VSDs and LED drivers
Harmonic-rich loads need detuned correction, not a standard capacitor bank.
How we work
From survey to handover
Bill and single-line review
We read recent TNB bills and the single-line diagram to find where correction should sit.
Load profiling
Analyser installed safely at the incomer; data captured across real production days.
Design and installation
APFC panel or capacitor bank sized from the data, installed with proper protection and cabling.
Commissioning and report
Controller set up, steps tested under load, and before-and-after power factor documented.
FAQ
Frequently asked questions
What is power factor and why does TNB penalise a low one?
Why do you profile the load before quoting a capacitor bank?
Do I need a detuned reactor?
Can you repair an existing capacitor bank?
How long does the installation take?
Get a quote
Ask us about power factor correction
Fill in the short form — we open WhatsApp with your details prefilled. Or WhatsApp / call us directly.
Cut the penalty, not the production. Free site visit & quote.
Free site visit & quote · registered contractor · tested & documented.
Petaling Jaya · Kuala Lumpur · Puchong · Shah Alam · Klang · Subang Jaya · Kajang · Cheras · Ampang · Cyberjaya · Seremban · Kota Damansara · Kepong · Setia Alam · Bangi